Southern LNG Inc.
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 12/01/2001, Docket: CP99-582-004, Status: Effective
Original Sheet No. 50 Original Sheet No. 50 : Effective
GENERAL TERMS AND CONDITIONS
(Continued)
(iii) The flowing temperature of the gas shall be determined for the purpose of
measured volume correction. Volume shall be corrected for each degree of
variation in the flowing temperature from 60 degrees Fahrenheit. The flowing
temperature will be measured by RTD's, thermocouples, thermometers, etc. and
shall be either (1) recorded using charts, digital recorders, etc., in which
case the temperature at which gas was measured for the period of such record
shall be the arithmetic average of the record during the period of time
during which gas was flowing; or (2) used for on-site flow computations in
electronic flow computers in which case the instantaneous measurement of
temperature will be used in such computations. Where no temperature measuring
device is installed, the temperature of the gas shall be assumed to be 60
degrees Fahrenheit.
(iv) A specific gravity correction shall be applied to measured volumes. The
specific gravity to be used for such correction shall be determined at an
appropriate location by a gravitometer, chromatograph, or other device of
standard manufacture and shall be either (1) recorded using charts, digital
recorders, etc., in which case an arithmetic average (to be determined during
the period of time during which flow was occurring at the location of the
specific gravity recorder) of such record shall be the specific gravity of
the gas being measured; or (2) used for flow computations in electronic flow
computers in which case the value of the specific gravity being measured will
be used as appropriate in such computations. If a specific gravity measuring
device is not installed or available at an appropriate location, then
specific gravity shall be determined by a mutually agreeable method.