Midwest Gas Storage, Inc.
First Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 05/15/1994, Docket: CP90-454-004, Status: Effective
Original Sheet No. 520 Original Sheet No. 520 : Effective
preceding test, the previous recordings of such equipment
shall be corrected to zero error for any period which is
known definitely or agreed upon, such correction shall be
for a period extending over one-half of the time elapsed
since the date of the last test.
8. QUALITY
8.1 Heat Content. Heat content shall mean the gross heating
value per cubic foot of Gas delivered at each Point of
Receipt and Point of Delivery. The Gas at each Point of
Receipt shall have a heat content not greater than 1200
BTUs per cubic foot nor less than 950 BTUs per cubic foot
when determined on a dry basis. Midwest shall have the
right to waive such BTU content limits if, in Midwest's
sole opinion, Midwest is able to accept Gas with a BTU
content outside such limits without affecting Midwest's
operations. The total heating value per cubic foot of Gas
shall be determined at each Point of Receipt and each Point
of Delivery by one of the following methods:
(a) by means of an instrument of standard manufacture
installed to measure the heating value of the Gas
being delivered at the Point of Receipt or the Point
of Delivery.
(b) at intervals of not more than six (6) Months by means
of an instrument of standard manufacture and a sample
of Gas from the Gas stream from which Gas is being
delivered at the Point of Receipt or the Point of
Delivery.
(c) other method mutually agreed upon by both parties.
For the purpose of calculating receipts and deliveries, the
heat content of the Gas so determined at each such point
shall be deemed to remain constant at such point until the
next determination. The unit of quantity for the purpose
of determining total heating value shall be one (1) cubic
foot of Gas at a temperature of sixty degrees (60ø)
Fahrenheit and an absolute pressure of 14.73 psia.
8.2 Freedom from Objectionable Matter. The Gas received and
delivered hereunder shall be merchantable Natural Gas and: