Pine Needle LNG Company, LLC
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 05/01/1999, Docket: CP96- 52-003, Status: Effective
Original Sheet No. 47 Original Sheet No. 47 : Effective
GENERAL TERMS AND CONDITIONS
(Continued)
5. MEASUREMENT EQUIPMENT (Continued)
(d) Inaccurate Meter
In the event a meter is out of service, or registering inaccurately,
the quantity of natural gas received or delivered shall be determined,
(i) By using the registration of any check meter or meters if
installed and accurately registering, or, in the absence of
(i),
(ii) By correcting the error or the percentage of error if
ascertainable by calibration, test, or mathematical
calculation, or in the absence of both (i) and (ii), then
(iii) By estimating the quantity of receipts or deliveries during
periods under similar conditions when the meter was
registering accurately.
(e) Verification
The accuracy of Pine Needle's measurement equipment shall be verified
by Pine Needle at reasonable intervals, and, if requested, in the
presence of representatives of Customer, but Pine Needle shall not be
required as a matter of routine to verify the accuracy of such
equipment more frequently than once in any thirty (30) day period.
In the event either party shall notify the other that it desires a
special test of any measuring equipment, the parties shall cooperate
to secure a prompt verification of the accuracy of such equipment.
The expense of such special tests as may be requested by Customer
shall be borne by Customer if the measuring equipment, by such tests,
is found to be correct.