Saltville Gas Storage Company L.L.C.
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 02/07/2008, Docket: RP08-156-000, Status: Effective
First Revised Sheet No. 142 First Revised Sheet No. 142 : Effective
Superseding: Original Sheet No. 142
GENERAL TERMS AND CONDITIONS
(Continued)
13. MEASUREMENT
13.1 The unit of volume for measurement of all quantities of Gas Stored
by Saltville or delivered to and received from storage hereunder
shall be one (1) Cubic Foot of Gas at the base temperature of
sixty degrees Fahrenheit (60 degrees F) and at an absolute
pressure of fourteen and seventy-three hundredths (14.73) pounds
per square inch. All fundamental constants, observations,
records, and procedures involved in determining and/or verifying
the quantity and other characteristics of Gas delivered hereunder
shall, unless otherwise specified herein, be in accordance with
the standards prescribed in Report No. 3 of the American Gas
Association, as now and from time to time amended or supplemented.
All measurements of Gas shall be determined by calculation into
terms of such unit. All quantities given herein, unless expressly
stated otherwise, are terms of such unit. Notwithstanding the
foregoing, it is agreed that, for all purposes, the Btu content of
the Gas received and delivered by Saltville hereunder shall be
measured on a "dry" basis rather than a fully saturated or "wet"
basis. Standardize the reporting basis for Gas volumes as cubic
foot at standard conditions of 14.73 psia, 60 degrees F and dry.
For Gas volumes reported in cubic meters, the standard conditions
are 101.325 kPa, 15 degrees C, and dry.
13.2 Saltville shall install, maintain and operate, or cause to be
installed, maintained and operated, the measurement facilities
required hereunder. Said measurement facilities shall be so
equipped with orifice meters, recording gauges, or other types of
meters of standard make and design commonly acceptable in the
industry, as to accomplish the accurate measurement of Gas
delivered hereunder. The retrieval of data, calibrating and
adjustment of meters shall be done by Saltville or its agent.
13.3 In the event volumes measured through Saltville's system shall
result in either gains or losses then Saltville shall allocate any
such gains or losses to all parties having Gas in Saltville's
facilities in proportion to the quantity of Gas of each such part
in Saltville's facilities at the time of any such gain or losses
unless such gain or losses are the result of Saltville's gross
negligence or willful misconduct.