Natural Gas Pipeline Company Of America
Seventh Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 04/18/2008, Docket: RP08-319-000, Status: Effective
Original Sheet No. 471 Original Sheet No. 471 : Pending
GENERAL TERMS AND CONDITIONS
----------------------------
(b) If a continuous sampler is installed, then the
heating value of the gas so taken shall be applied prospectively to
the gas delivered beginning no later than the first of the following
month. If gas samples are taken, then the heating value of the
sample so taken shall be applied prospectively to the gas delivered
beginning no later than the first of the following month and used
until a new sample is taken. When a chromatograph is used to update
heating values into an electronic flow computer, either locally or
remotely, the average heating value shall be considered as the
average heating value recorded by the electronic flow computer. All
heating value determinations made with a chromatograph shall use
physical constants for gas compounds as outlined in the AGA Report
#3, Third Edition, October, 1990 titled "Orifice Metering of Natural
Gas" or (at Natural's discretion) any subsequent amendment or
revision to such report. If tested against a certified standard
sample, the heating value determining device shall be considered
correct if it shall check in such test within ten (10) Btu per cubic
foot.
24.4 DETERMINATION OF FLOWING TEMPERATURE
The temperature of the gas flowing through the meter or
meters shall be determined by the continuous use of a recording
thermometer installed so that it will properly record the
temperature of the gas flowing through the meter or meters. The
temperatures recorded during periods of flow each day shall be used
in computing the volumes of gas for that day.
24.5 DETERMINATION OF SPECIFIC GRAVITY
(a) At Natural's sole option, the specific gravity
value of the gas may be determined by the use of a chromatograph, by
the use of a continuous sampler, or by the taking of gas samples.
(b) If a continuous sampler is installed, the specific
gravity value of the gas so taken shall be applied prospectively to
the gas delivered beginning no later than the first of the following
month. If gas samples are taken, then the specific gravity value of
the sample so taken shall be applied prospectively to the gas
delivered beginning no later than the first of the following month
and used until a new sample is taken. When a chromatograph is used
to update specific gravity values into an electronic flow computer,
either locally or remotely, the average specific gravity value shall
be considered as the average specific gravity value recorded by the