Williston Basin Interstate Pipeline Co.
Second Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 06/01/1997, Docket: RP97-352-000, Status: Effective
Third Revised Sheet No. 106 Third Revised Sheet No. 106 : Effective
Superseding: Second Revised Sheet No. 106
RATE SCHEDULE FS-1
FIRM STORAGE SERVICE (Continued)
2. APPLICABILITY AND CHARACTER OF SERVICE
2.1 Storage service hereunder, up to the Maximum Storage
Deliverability Quantity (MSDQ) and the Maximum Storage
Injection Quantity (MSIQ) specified in Exhibit A to the Service
Agreement, each as adjusted pursuant to the Capacity Adjustment
Provision (CAP) (described in Subsection 1.47 of the General
Terms and Conditions of this Tariff), and up to the Maximum
Storage Capacity Quantity (MSCQ), as adjusted to reflect the
weighted average of the actual Btu content of gas held in
storage for such Shipper, shall be considered firm, and is not
subject to curtailment or interruption at any time, except as
provided in the General Terms and Conditions.
2.2 Storage service hereunder shall consist of the acceptance by
Transporter of gas for injection into storage, the retention of
such gas in storage, and the withdrawal of such gas from
storage for transportation, all in accordance with the
provisions set forth in the Service Agreement.
2.3 Gas is to be injected into storage on a firm basis during the
injection season commencing on April 1 and continuing through
October 31 of the same year. Gas is to be withdrawn from
storage on a firm basis during the withdrawal season beginning
on November 1 and continuing through the following March 31.
Storage injections shall be allowed during the withdrawal
season and withdrawals shall be allowed during the injection
season on a reasonable-efforts basis. Such reasonable-efforts
injections and/or withdrawals shall have a higher priority than
all interruptible storage gas for scheduling and interruption
purposes.
2.4 Provided Shipper has the requisite gas in storage, the MSDQ for
which Shipper has contracted, as adjusted pursuant to the CAP,
will be available for any one hundred days during the
withdrawal season. Shipper shall be required to inject its
MSCQ, as adjusted to reflect the weighted average of the actual
Btu content of gas held in storage for such Shipper, set forth
in the Service Agreement into storage by November 1. In the
event that Shipper fails to inject such MSCQ by November 1, the
above-referenced one hundred days of service will be reduced
accordingly.