Nora Transmission Company

First Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 11/02/1998, Docket: RP99- 78-000, Status: Effective

Second Revised Sheet No. 120A Second Revised Sheet No. 120A : Superseded

Superseding: First Revised Sheet No. 120A

GENERAL TERMS AND CONDITIONS (Continued)

 

from Pipeline, along with upstream and

downstream contract numbers and contact person;

 

(vii) If deliveries are to be into a pool on another

pipeline system, the identity of the pool

operator and verification that the pool operator

will be responsible for any imbalances;

 

(viii) The portion of the nominated quantities

designated for imbalance correction purposes;

 

(ix) Whether the nomination will roll over after the

end of the Nomination Period; and

 

(x) Any business-conditional and/or mutually-

agreeable data elements which may be needed for

the Pipeline to perform the service and satisfy

the other operational constraints on its system.

 

13.2 Intra-Day Nominations

 

The Customer shall have the right to submit an intra-day

nomination prior to gas flow to revise its scheduled quantities,

point(s) of receipt, and/or point(s) of delivery on a prospective

basis. Such intra-day nomination shall only be implemented to

the extent that the Pipeline is able to confirm the receipt and

delivery of such gas. There are two intra-day nomination cycles:

(i) intra-day nomination 1 cycle, a nomination must leave the

control of the Customer either through the Pipeline's electronic

communications system, EDI, or via facsimile no later than

10:00 a.m. CCT to be received by the Pipeline by 10:15 a.m. CCT on

the same day of gas flow to be effective at 5:00 p.m. CCT that same

day. The Pipeline will provide a quick response by 10:30 a.m. CCT,

and (ii) intra-day nomination 2 cycle, a nomination must leave the

control of the Customer no later than 5:00 p.m. CCT to be received

by the Pipeline by 5:15 p.m. CCT on the same day of gas flow to be

effective 9:00 p.m. CCT that same day. The Pipeline will provide

a quick response by 5:30 p.m. CCT. Intra-day nominations may be

used to nominate new supply or market. An intra-day nomination

shall specify Customer's service requirement for one day only and

shall include the effective date and time. Intra-day nominations

do not replace the remainder of a standing nomination. There is no

need to re-nominate if intra-day nomination modifies existing

nomination. There is no limitation as to the number of intra-day

nominations which a Customer may submit at any one standard