4. QUALITY
4.1 QUALITY SPECIFICATIONS
a. The natural gas to be delivered by Transporter shall be of
merchantable quality.
b. Unless otherwise agreed to in the Service Agreement, gas
tendered at each Point of Receipt shall comply with the following
quality specifications:
(1) At a base pressure of 14.73 p.s.i.a. and a base
temperature of 60 degrees Fahrenheit, such gas shall not contain
more than:
(a) 1/4 grain of hydrogen sulphide per 100 cubic
feet;
(b) 5 grains of total sulphur per 100 cubic feet;
(c) 1 grain of mercaptans per 100 cubic feet;
(d) 2.0 percent by volume of carbon dioxide;