Trailblazer Pipeline Company
Fourth Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 12/28/2007, Docket: RP08-168-000, Status: Effective
Original Sheet No. 229 Original Sheet No. 229 : Effective
GENERAL TERMS AND CONDITIONS
----------------------------
(e) Shall be delivered at a temperature not in excess
of one hundred twenty degrees Fahrenheit (120 F.) or less than
twenty degrees Fahrenheit (20 F.);
(f) Shall not contain more than three percent (3%) by
volume of carbon dioxide;
(g) Shall not contain water vapor in excess of five (5)
pounds per million (1,000,000) cubic feet of gas; and
(h) Shall not contain any hydrocarbon fractions which
might condense to free liquids in the line under normal pipeline
conditions; provided that this subsection (h) shall not apply to
gathering systems or lateral lines.
24.3 TOXIC AND HAZARDOUS SUBSTANCES
Shipper agrees to supply or cause its designee to supply
to Trailblazer upon demand, at any time and from time to time, a
sample of liquids removed from the gas stream at any Receipt Point,
whether removed by a coalescer or otherwise, for analysis at a
laboratory of Trailblazer's choosing. If at any time PCBs or any
other toxic substances or chemicals that Trailblazer deems hazardous
and/or in any way unsafe for transportation are found in the liquid
samples supplied to Trailblazer by Shipper, Trailblazer may in its
sole discretion immediately cease the receipt of such gas and any
associated liquids through its facilities. Upon proof that such
toxic or hazardous substances are no longer present at levels deemed
unsafe by Trailblazer, Trailblazer shall restore service to Shipper
at the affected Receipt Point.
24.4 NON-CONFORMING GAS
If at any time, gas tendered under the Agreement shall
fail to conform to any of the quality specifications set forth above
the receiving party may, at its option, refuse to accept delivery
pending correction of the deficiency by the delivering party.
24.5 POSTING OF GAS QUALITY INFORMATION
Trailblazer posts information on gas quality on its
system as described in Section 18.1(a) of these General Terms and
Conditions.