GENERAL TERMS AND CONDITIONS
----------------------------
22.6 MEASURING EQUIPMENT
Unless otherwise agreed upon, Trailblazer will install,
maintain and operate or cause to be installed, maintained and
operated, measuring stations equipped with flow meters and other
necessary metering and measuring equipment by which the volumes of
gas received and Equivalent Volumes delivered hereunder shall be
determined. Shipper may install check measuring equipment at its
own cost and expense; provided such equipment shall be so installed
as not to interfere with the operations of Trailblazer.
Trailblazer and Shipper, in the presence of each other, shall have
access to the other's measuring equipment at all reasonable times
but the reading, calibrating and adjusting of electronic computer
components and/or mechanical recording instruments thereof and the
changing of charts shall be done only by the equipment owner or
such owner's representative, unless otherwise agreed upon. Both
Trailblazer and Shipper shall have the right to be present at the
time of any installing, reading, cleaning, changing, repairing,
inspecting, testing, calibrating, or adjusting done in connection
with the other's measuring equipment; provided, however, failure of
either Trailblazer or Shipper to witness such an operation shall
not affect the validity of such operation in any way. The records
from such measuring equipment shall remain the property of its
owner, but upon request, each will submit within ten (10) days to
the other its records and charts, together with calculations
therefrom, for inspection, subject to return within thirty (30)
days after receipt thereof. The measurement equipment of Shipper
shall be for check purposes only and, except as expressly provided
herein, shall not be used in the measurement of gas for purposes
hereof.
22.7 ORIFICE METERS
Orifice meters shall be installed and gas volumes
computed, in accordance with the standards prescribed in ANSI/API
2530 entitled, "Orifice Metering of Natural Gas," which
incorporates Gas Measurement Committee Report #3 of the American
Gas Association, revised and reprinted, September 1969, and any
subsequent amendments Trailblazer may adopt in the exercise of its
reasonable judgment.