12.3 Unit of Measurement and Metering Base. The standard reporting
basis for Btu is 14.73 psia and 60 degrees F (101.325 kPa, and 15 degrees C,
and dry). The standard reporting basis for gigacalorie is 1.035646 Kg/cm2 and
15.6 degrees C, and dry. The standard reporting basis for gas volumes is
cubic foot at standard conditions of 14.73 psia, and 60 degrees F, and dry.
For gas volumes reported in cubic meters, the standard conditions are 101.325
kPa and 15 degrees C, and dry.
12.4 Atmospheric Pressure. For the purpose of measurement,
calculation and meter calibration, the average absolute atmospheric
(barometric) pressure will be based on the actual altitude at each point of
measurement irrespective of variations in natural atmospheric pressure from
time to time. When electronic computer measurement is used, the atmospheric
pressure will be the barometric pressure calculated for the elevation at the
point of measurement.
12.5 Flowing Temperature. The temperature of the gas will be
determined at the points of measurement by means of a properly installed
recording thermometer or continuous electronic transducer input to a computer
(of standard manufacture selected by Southern Trails). When used with orifice
meters, the gas temperature device shall be installed and operated, and the
gas temperature quantities computed, in accordance with AGA Report No. 3, Part
2, API Chapter No. 21.1, and API Chapter 14.3. When used with turbine meters,
the gas temperature device shall be installed and operated, and the gas
temperature quantities computed, in accordance with AGA Report No. 7 and API
Chapter 21.1. When used with rotary meters, the gas temperature device shall
be installed and operated, and the gas temperature quantities computed, in
accordance with AGA ANSI B109.3 and API Chapter 21.1. When used with
ultrasonic meters, the gas temperature device shall be installed and operated,
and the gas temperature quantities computed, in accordance with AGA Report No.
9 and API Chapter No. 21.1.
12.6 Gross Heating Value and Specific Gravity.
(a) The determination of gross heating value and specific
gravity will be made from the composition by calculation using physical gas
constants for gas compounds as outlined in GPA Standard 2145-03 and GPA
Standard 2172-96, with any subsequent amendments or revisions that Southern
Trails may adopt.