Questar Pipeline Company
First Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 10/01/2009, Docket: RP09-1030-003, Status: Effective
Fifth Revised Sheet No. 121 Fifth Revised Sheet No. 121
Superseding: Fourth Revised Sheet No. 121
PART 2
GENERNAL TERMS AND CONDITIONS
(Continued)
Shipper's compressor and dehydration fuel responsibility =
(A/B) * C
A = Shipper's injection and withdrawal quantities for each month
at a particular peaking storage reservoir
B = The sum of PAL2 service, and of all shippers'
injection and withdrawal quantities for each month at that
particular peaking storage reservoir
C = Compressor and dehydration fuel for each month at that
particular peaking storage reservoir
* = Multiplication operator
14.4. All utility fuel associated with its PAL2 accounts will be
included as an operating expense and will not be part of the fuel-gas
reimbursement.
15. BILLING AND PAYMENT
All billing and payment procedures associated with peaking storage
service provided by Questar under Rate Schedule PKS shall be according to the
General Terms and Conditions of Part 1 of this tariff.
16. TITLE AND CLAIMS AGAINST GAS
The title requirements and shipper's obligation for the gas delivered
for storage are stated in the General Terms and Conditions of Part 1 of this
tariff.
17. LIABILITY
Questar's liability is limited as defined by § 20 of the General Terms
and Conditions of Part 1 of this tariff, provided further that Questar shall
not be liable for any loss, damage, or injury due to the intrinsic
geophysical characteristics of peaking storage reservoirs.