14.9 New Measurement Techniques. If a new method or
technique is developed for gas measurement, the new method
or technique may be substituted by Questar. Questar will
promptly inform all shippers of any new techniques adopted.
14.10. Rights Concerning Measurement Equipment
(a) Questar and the operator of any
interconnecting facility, in the presence of each other or
their contractually designated representative, may have
access to the other's measurement equipment at all
reasonable times for installing, reading, cleaning,
changing, repairing, inspecting, testing, calibrating or
adjusting done in connection with the other's measurement
equipment. Only the party owning the equipment may perform
these operations, unless otherwise agreed. The failure of
either party to witness such operations will not affect the
validity of the operations.
(b) The records from measurement equipment will
remain the property of the party owning the equipment, but
within ten days of a request, each will permit the other
party to inspect its records and data, together with related
calculations.
(c) The measurement equipment of the operator of
the interconnecting facility will be for check purposes only
and, except as expressly provided in these General Terms and
Conditions, will not be used in the custody measurement of
gas.
14.11 Calibration and Test of Measurement Equipment.
Questar will verify the accuracy of all measurement
equipment at reasonable intervals. Questar will provide
notice of regular inspections and calibrations of
measurement equipment and any routine orifice plate changes
to the operators of interconnecting facilities, and the
operators or other contractually designated representative
of shippers may attend the inspections or plate changes.