(Continued)
(iv) Unamortized or over-amortized variance quantities, as
described in Section 12.15(a)(iii), from the preceding January 1 through
December 31 amortization period.
(v) Projected annual scheduled transportation receipt
quantities for the next twelve months commencing on January 1 of each year.
Projected annual scheduled transportation receipts will be based on the
annual scheduled transmission receipt quantities for the preceding twelve
months ended September 30, as adjusted for anticipated changes in system
operations.
(b) Questar may elect to file an independent application for
authority to calculate and charge a separate FGRP for new facilities or
existing facilities that are operated in isolation from the remainder of
Questar's pipeline system.
13. QUALITY OF GAS
13.1 The gas received by Questar from shipper and
delivered by Questar to shipper shall conform to the following specifications:
(a) Heat Content. The gas delivered at each of the points of
receipt and delivery shall contain a gross heating value of not less than 950
Btu per cubic foot nor more than 1150 Btu per cubic foot.
(b) Hydrogen Sulfide. The gas shall not contain more than 1/4
grain of hydrogen sulfide per 100 cubic feet.
(c) Inert Substances. The gas shall not contain inert substances
in excess of three percent by volume.
(d) Liquids. Gas tendered for transportation at a receipt point
shall not contain any free liquids of any nature and shall conform to the CHDP
specification set forth in §§ 13.2 and 13.3.
(e) Merchantability. The gas shall be commercially free from
dust, gums, gum-forming constituents,