Canyon Creek Compression Company

Third Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 08/01/1999, Docket: RP99-417-001, Status: Effective

Substitute Second Revised Sheet No. 121A Substitute Second Revised Sheet No. 121A : Effective

Superseding: Substitute First Revised Sheet No. 121A

GENERAL TERMS AND CONDITIONS

----------------------------

 

(d) The standard quantity for nominations, confirmation and

scheduling is dekatherms per gas day in the United States, gigajoules

per gas day in Canada and gigacalories per gas day in Mexico. (For

reference, 1 dekatherm = 1,000,000 Btus; 1 gigajoule = 1,000,000,000

joules; and 1 gigacalorie = 1,000,000,000 calories.) For commercial

purposes, the standard conversion factor between dekatherms and

gigajoules is 1.055056 gigajoules per dekatherm and between dekatherms

and gigacalories is 0.251996 gigacalories per dekatherm. The standard

Btu is the International Btu, which is also called the Btu (IT); the

standard joule is the joule specified in the SI system of units. The

International Btu is specified for use in the gas measurement standards

of the American Gas Association, the American Petroleum Institute, the

Gas Processors Association and the American Society for Testing

Materials. For non-commercial purposes, these associations note that

the exact conversion factor is 1.05505585262 Gigajoules per Dekatherm.

 

9.2 STANDARD NOMINATION CYCLES

Canyon supports the following standard nomination cycles:

 

 

(a) The Timely Nomination Cycle: 11:30 a.m. for nominations

leaving control of the nomination party; 11:45 a.m. for receipt of

nominations by Canyon; noon to send Quick Response; 3:30 p.m. for

receipt of completed confirmations by Canyon from upstream and

downstream connected parties; 4:30 p.m. for receipt of scheduled

quantities by shipper and point operator (central clock time on the day

prior to flow).

 

(b) The Evening Nomination Cycle: 6:00 p.m. for nominations

leaving control of the nominating party; 6:15 p.m. for receipt of

nominations by Canyon; 6:30 p.m. to send Quick Response; 9:00 p.m. for

receipt of completed confirmations by Canyon from upstream and

downstream connected parties; 10:00 p.m. for Canyon to provide

scheduled quantities to affected shippers and point operators, and to

provide scheduled quantities to bumped parties (notice to bumped

parties), (central clock time on the day prior to flow).

 

Scheduled quantities resulting from an Evening

Nomination that does not cause another Service Requester on Canyon to

receive notice that it is being bumped should be effective at 9:00 a.m.

on the gas Day; and when an Evening Nomination causes another Service

Requester on Canyon to receive notice that it is being bumped, the

scheduled quantities should be effective at 9:00 a.m. on the gas Day.