Ozark Gas Transmission, L. L. C.

First Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 11/01/2008, Docket: RP08-617-000, Status: Effective

Original Sheet No. 110 Original Sheet No. 110

 

GENERAL TERMS AND CONDITIONS (continued)

 

its records and charts, together with calculations therefrom, for

inspection, subject to return within thirty (30) Days after

receipt thereof. The measurement equipment of Shipper shall be for

check purposes only and, except as expressly provided in an

executed Service Agreement, shall not be used in the measurement

of Natural Gas for purposes of such Service Agreement.

 

3.6 Calibration and Test of Meters. The accuracy of all

measuring equipment shall be verified by Transporter at reasonable

intervals, and, if requested, in the presence of representatives

of Shipper, but neither Transporter nor Shipper shall be required

to verify the accuracy of such equipment more frequently than once

in any thirty (30) Day period. If either Transporter or Shipper

at any time desires a special test of any measuring equipment, it

will promptly notify the other and Transporter and Shipper shall

then cooperate to secure a prompt verification of the accuracy of

such equipment.

 

3.7 Correction of Metering Errors. If, upon any test, any

measuring equipment is found to be inaccurate, such equipment

shall be adjusted immediately to measure accurately. If upon any

test the measuring equipment in the aggregate is found to be

inaccurate by two percent (2%) or more at a recording

corresponding to the average hourly rate of Natural Gas flow for

the period since the last preceding test, previous recordings of

such equipment and any payments based thereon shall be corrected

at the rate of such inaccuracy for any period which is known

definitely or agreed upon, but in case the period is not known

definitely or agreed upon, such correction shall be for a period

extending over one-half of the time elapsed since the date of the

last test, not exceeding a correction period of sixteen (16) Days.

 

3.8 Failure of Measuring Equipment. In the event any measuring

equipment is out of service or out of repair so that the quantity

of Natural Gas received or delivered through such meter cannot be

ascertained or computed from the readings thereof, the