Ozark Gas Transmission, L. L. C.
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 11/01/1998, Docket: CP98-266-005, Status: Effective
Substitute Original Sheet No. 74 Substitute Original Sheet No. 74 : Effective
GENERAL TERMS AND CONDITIONS (continued)
Transporter will permit prior period adjustments to
measurement data for six (6) Months from the billing
Month. Shippers will have an additional three (3) Months
to rebut an adjustment. Transporter will permit
adjustments after this time period, if all affected
parties agree. This time limitation will not apply in
the case of deliberate omission or misrepresentation or
mutual mistake of fact, and parties' other statutory or
contractual rights will not otherwise be diminished by
this provision.
4. QUALITY
4.1 Heat Content. The Natural Gas delivered at the Point(s)
of Receipt and the Point(s) of Delivery under an executed
Service Agreement shall contain a Heating Value of not
less than 950 Btu per cubic foot. The Heating Value
shall be determined by Transporter by the installation of
a recording calorimeter, a continuous sample accumulator,
an onstream chromatograph, or by means of spot samples,
provided, however, that in lieu of a recording
calorimeter, Transporter may determine the Heat Content
on the basis of samples taken at periodic intervals. If
periodic determinations of Heating Value are made, the
initial determination is to be made within sixty (60)
Days after the date of initial deliveries of Natural Gas
under an executed Service Agreement and subsequent
determinations shall be made each three (3) Months
thereafter. The recording calorimeter mentioned herein
shall be tested periodically using a reference sample of
Natural Gas of known Heating Value.
4.2 Freedom from Objectionable Matter. The Natural Gas
received and delivered under an executed Service
Agreement:
(a) Shall be commercially free from dust, gums,
gum-forming constituents, dirt, impurities or other
solid or liquid matter which might interfere with
its merchantability or cause injury to or
interference with proper operations of the lines,
regulators, meters and other equipment of
Transporter;
(b) Shall not contain more than one-quarter (1/4) of one
(1) grain of hydrogen sulphide per one hundred (100)
cubic feet of Natural Gas. Subject to the
provisions of Section 8 of Transporter's Rate
Schedules FTS and ITS, theprovisions of this Section
4.2(b) do not apply to wells connected to
Transporter's system as of October 1, 1993 which
currently exceed the 1/4