Young Gas Storage Company, Ltd.
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 08/01/2010, Docket: RP10-921-000, Status: Effective
Fourth Revised Sheet No. 47A Fourth Revised Sheet No. 47A
Superseding: Third Revised Sheet No. 47A
GENERAL TERMS AND CONDITIONS
(Continued)
1.1 (Continued)
YOUNG STORAGE FIELD
THE AVAILABLE DAILY INJECTION QUANTITY RULES and FORMULA
%MAC = Current Inventory/MAC
------------------------------------
%MDIQ Calculation
If the %MAC is < 100% and > 0%
then use the FORMULA to find the %MDIQ (1)
FORMULA (2,3):
%MDIQ = 100.0 - (%MAC * 1.0111774) + (%MAC^2 * 0.0051126)
------------------------------------
ADIQ Calculation (4)
ADIQ = (%MDIQ/100) * MDIQ
Round to the nearest whole Dekatherm (an integer)
------------------------------------
Notes: (1) The formula applies only when inventory is < than MAC and
> 0. If inventory is > or = to MAC, then set ADIQ = 0.
If inventory is < or = 0, set ADIQ = MDIQ.
(2) In the context of this formula, the %MAC and %MDIQ values
are taken as whole numbers, and not as decimal only
numbers (i.e. if the value is 40% use 40.0 not .40, or if
it is 36.1234% use 36.1234 not 0.361234).
(3) The coefficients are entered with seven decimal places.
The table is calculated with seven decimal places, and
then rounded for display purposes.
(4) All calculations are initially performed utilizing seven
decimal places. The final ADIQ, however, is rounded to
the nearest whole number.