MarkWest Pioneer, L.L.C.

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 04/01/2009, Docket: RP09-321-000, Status: Effective

Original Sheet No. 39 Original Sheet No. 39

 

GENERAL TERMS AND CONDITIONS

(Continued)

 

2. GAS QUALITY

 

2.1. Specifications

 

2.1.1. In order to permit delivery into downstream facilities, the Gas

received under any FT or IT Agreement by Transporter on any portion

of the system, shall meet the following requirements, unless

otherwise agreed:

 

a) Shall be free from objectionable liquids, odors, solid

matter, dust, gums, and gum forming constituents, or any other

substance which might interfere with the merchantability of the Gas

stream, or cause interference with proper operation of the lines,

meters, regulators, other appliances through which it may flow, or

transportation through any downstream pipeline;

 

b) Shall contain not more than 7 pounds of water vapor per one

thousand (1,000) Mcf;

 

c) Shall contain not more than .25 grain of hydrogen sulfide

per one hundred (100) cubic feet of Gas;

 

d) Shall contain not more than 5 grains of total sulphur per

one hundred (100) cubic feet of Gas, including mercaptans and

hydrogen sulfide;

 

e) Shall contain not more than 2 percent by volume of carbon

dioxide;

 

f) Shall contain not more than 0.1 percent by volume of

combined oxygen;

 

g) Shall have a temperature of not more than 120 degrees

Fahrenheit and shall have a minimum temperature of not less than 40

degrees Fahrenheit;