GENERAL TERMS AND CONDITIONS
(continued)
(f) The heating value shall be determined by using a
suitably located acceptable calorimeter, or
calculation from fractional analysis, or methods
outlined in A.G.A. Gas Measurement Committee Report
No. 5, as may be amended or modified from time to
time, or other mutually accepted methods.
(g) The MMBTU delivered shall be calculated either by
multiplying the Mcf Delivered by a fraction the
numerator of which is the Heat Content and the
denominator of which is 1,000.
3.3 Each test provided in this section shall be used in the
computation for the measurement of receipts and deliveries
until the next succeeding test.
4. MEASUREMENT EQUIPMENT:
4.1 Installation and Operation by Western - Western shall
install, maintain and operate, at its own expense, at or
near each Delivery Point and Receipt Point, a measuring
station properly equipped with meters and other necessary
equipment by which the quantity of gas delivered to Western
or to Buyer or Shipper, as the case may be, shall be
measured. The quantity of gas received or delivered
hereunder shall be measured in accordance with Section 3.2
and with the published recommendations of the American Gas
Association as amended or superseded from time to time.
Where Buyer and Western so agree, Buyer, at the request of
Western, will change the charts on the meters at the
Receipt Point(s) and Delivery Point(s) daily or so
frequently as requested and send them promptly by mail to
Western without charges or cost to Western.
4.2 Calibration, Test of and Access to Meters - Buyer or
Shipper shall have the right to have representatives
present at the time of any installing, cleaning, changing,
repairing, inspecting, testing, calibrating or adjusting
done in connection with Western's measuring equipment used
in the measurement of receipts or deliveries of gas. The
accuracy of Western's measuring equipment may be verified