Puget Sound Energy, Inc.
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 09/30/2008, Docket: RP08-597-000, Status: Effective
Original Sheet No. 139 Original Sheet No. 139
EXHIBIT F
(revised August 29, 2008 pursuant to Amendment No. 9)
to the
JACKSON PRAIRIE
GAS STORAGE PROJECT AGREEMENT
OPERATING RULES
Part 1: The Seasonal Working Gas Quantity for an Owner during any Storage
Cycle is the least of:
a) The quantity of Owner's Working Gas Inventory at the
beginning of such Storage Cycle divided by 0.97; or
b) The least quantity of Owner's Working Gas
Inventory at any time after August 31st and on or before
September 30th of the preceding Storage Cycle divided by
0.80; or
c) The least quantity of Owner's Working Gas Inventory at
any time after June 30th and on or before September 30th of
the preceding Storage Cycle divided by 0.35; or
d) The Owner's Firm Working Gas Capacity.
Part 2: The Firm Withdrawal Deliverability of an Owner on any Day is as
follows:
a) When the Owner's Available Working Gas Inventory at
the start of the Gas Day equals or exceeds 60% of the
Owner's Firm Working Gas Capacity, the Firm Withdrawal
Deliverability of such Owner shall be 100% of the maximum
Firm Withdrawal Deliverability set forth for that Owner on
Exhibit E.
b) When the Owner's Available Working Gas Inventory
at the start of the Gas Day is less than 60% but greater
than 15% of the Firm Working Gas Capacity of such Owner, the
Firm Withdrawal Deliverability of such Owner shall be
reduced by 2.0% of the maximum Firm Withdrawal
Deliverability set forth for that Owner on Exhibit E for
every 1% that the Available Working Gas Inventory for the
account of that Owner is below 60% of the Firm Working Gas
Capacity of such Owner.
c) When the Owner's Available Working Gas Inventory at the
start of the Gas Day is equal to or less than 15% of the
Owner's Firm Working Gas Capacity, the Firm Withdrawal
Deliverability shall be reduced to 10% of the maximum Firm
Withdrawal Deliverability set forth for that Owner on
Exhibit E; provided that when the Available Working Gas
Inventory of such Owner is zero, the Firm Withdrawal