Viking Gas Transmission Company
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 06/01/1991, Docket: GT91- 25-000, Status: Effective
First Revised Sheet No. 81A First Revised Sheet No. 81A : Superseded
Superseding: Original Sheet No. 81A
GENERAL TERMS AND CONDITIONS (Continued)
effect compliance with such requirements (the installation of such equipment shall
be subject to prior approval of Seller as to the design and construction of such
facilities, which approval shall not be unreasonably withheld);
(c) all gas shall not contain more than twenty (20) grains of total sulphur, nor more
than one fourth (1/4) of one grain of hydrogen sulphide per one hundred (100) cubic
feet;
(d) not contain more than two-tenths of one percent (0.2%) by volume of oxygen, and
Buyer shall make every reasonable effort to keep the gas free of oxygen;
(e) not contain more than four percent (4%) by volume of a combined total of carbon
dioxide and nitrogen components; provided, however, that the total carbon dioxide
content shall not exceed three percent (3%) by volume.
(f) have a temperature of not more than one hundred twenty degrees (120ø) Fahrenheit;
(g) have been dehydrated by Buyer for removal of entrained water present therein in a
vapor state, and in no event contain more than seven (7) pounds of entrained water
per million cubic feet, at a pressure base of fourteen and seventy three hundredths
(14.73) pounds per square inch and a temperature of sixty degrees (60ø) Fahrenheit
as determined by dew-point apparatus approved by the Bureau of Mines or such other
apparatus as may be mutually agreed upon.
2. If the gas offered for delivery by Seller shall fail at any time to conform to any of the
specifications set forth in Section 1 of this Article, then Buyer shall notify Seller of
such deficiency and thereupon may at Buyer's option refuse to accept delivery pending
correction by Seller. Upon Seller's failure promptly to remedy any deficiency in quality
as specified in Section 1 of this Article, Buyer may accept delivery of such gas and may
make changes necessary to bring such gas into conformity with such specifications, and
Seller may reimburse Buyer for any reasonable expense incurred by it in effecting such
changes.
3. The design and construction of any facilities to be installed by Buyer in order to comply
with the quality specifications in Article II Section 1 shall be approved by Seller prior
to such facilities being placed in service.
4. Tests to determine sulphur, hydrogen sulphide, oxygen, carbon dioxide and nitrogen
content shall be made by approved standard methods in general use in the gas industry.
5. As to gas which fails to meet the quality specifications set out in Section 1 of this
Article II, or, if applicable, the quality specifications set out in the Transportation
Contract or applicable Rate Schedule, Seller shall have the right to refuse to accept