Gulf South Pipeline Company L P
Sixth Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 12/31/2000, Docket: GT01- 6-000, Status: Effective
Original Sheet No. 4902 Original Sheet No. 4902 : Effective
. Gulf South Pipeline Company LP
Upstream/Downstream Date:__________________
Predetermined Allocation Agreement (PDA) Page _______ of _______
To:___________________ Meter #:__________ Meter Name:____________________________
Gulf South Pipeline Company LP Fax Nos. Circle the appropriate # below:
Customer Service Department (713) 544-6257
P.O. Box 1478 (713) 544-4184
Houston, TX 77251-1478
1. PDA for the 1st of the month through the end of the month.
From:___________________________ 2. Revised PDA for the 1st through month end due to a new
Company:________________________ Customer or contract that did not have nominations on the 1st.
Address:________________________
Phone:__________________________ Effective Date of PDA:____________ Ending Date of PDA:____________
______________________________________________________________________________________________________________________
Up/Down Up/Down ID Up/Down Cnt# Pkg. ID Over priority when gas flow exceeds Under priority when gas flow is
nominations. (Every Customer gets all less than nominations. (One or
nominations, and one or more Customers more Customers will not receive all
receive excess volume under 120%) nominated.)
Note (1) Note (2)
______________________________________________________________________________________________________________________
______________________________________________________________________________________________________________________
______________________________________________________________________________________________________________________
Notes: 1. If one up/down Customer or contract or package ID should receive all volume in excess of nominations, write
SWING on the appropriate line above. If two or more up/down Customers or contracts or package ID should
receive all volume in excess of nominations, those up/down Customers contracts or package ID should have
the highest number. All volume in excess of nominations will be prorated to those up/down Customers or
contracts or package ID based on nominations. Volumes in excess of 120% of nominations on any day will be
allocated to Unauthorized Gas pursuant to Section 12.5 of Gulf South's FERC Gas Tariff.
2. If an under priority is not listed for each contract and/or package ID, the default allocation method in
Section 12 of Gulf South's FERC Gas Tariff will govern. The lowest number listed on this PDA (i.e. 10), will
receive its nomination first, and the highest number listed (i.e. 90) will be the first to get cut or
receive less than nominated. Write the same number for contracts and/or package ID that should be
prorated.
3. In the event that this meter is affected by a supply or capacity constraint and notice is given pursuant to
Sections 10, 11 or 13 of Gulf South's FERC Gas Tariff, then Gulf South's default allocation methodology shall take
precedence over this agreement, and a daily allocation will be performed for that constrained period.
4. For further information on PDA's, refer to Sections 10, 11, 12 and 13 of Gulf South's FERC Gas Tariff.
5. Gulf South shall not be liable for and the party submitting this PDA shall indemnify and hold Gulf South harmless
from, any loss, costs, claims, expenses, penalties, or damages that directly or indirectly result from
Gulf South complying with this PDA, except for those instances where the loss, costs, claims, expenses,
penalties or damages arise as a result of Gulf South's negligence or willful misconduct.
6. PDA information must be submitted at same level as nomination.