Gulf South Pipeline Company L P
Sixth Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 08/01/2007, Docket: RP07-149-000, Status: Suspended
Second Revised Sheet No. 901 Second Revised Sheet No. 901 : Suspended
Superseding: First Revised Sheet No. 901
GENERAL TERMS AND CONDITIONS
Section 2
(Continued)
(h) Liquids - The gas shall be commercially free of water and
other objectionable liquids at the temperature and pressure
at which the gas is delivered and the gas shall not contain
any hydrocarbons which might condense to free liquids in
the pipeline under normal pipeline conditions and shall in
no event contain water vapor in excess of seven (7) pounds
per one million (1,000,000) cubic feet.
(i) Dust, Gums and Solid Matter - The gas shall be commercially
free of dust, gums, gumforming constituents or other
objectionable liquid or solid matter which might become
separated from the gas in the course of transportation
through the pipeline.
(j) Other Contaminates - The gas shall contain no carbon
monoxide, halogens or olifin hydrocarbons, and no more than
four hundred parts per million (400 ppm) by volume of
hydrogen.
(k) Heating Value - The heating value shall be determined on a
dry basis, unless otherwise mutually agreed by the parties.
Gas delivered shall contain an average Heating Value
meeting the following specifications:
(i) Minimum Btu: 950 Btu per cubic foot;
(ii) Maximum Btu: 1110 Btu per cubic foot subject to (iii)
below;
(iii) Pursuant to Section 2.2(a), (b), and (c), Gulf South
may post on its Internet Web Site a Maximum Btu
limit, for the entire system or by specific
operational area(s), less than 1110 Btu per cubic
foot to effectuate deliveries into a downstream
interconnecting pipeline with a specification below
1110 Btu; provided, however, that such posted Maximum
Btu limit shall not be less than 1075 Btu per cubic
foot.