Tres Palacios Gas Storage LLC
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 08/01/2008, Docket: RP08-424-000, Status: Effective
Original Sheet No. 142 Original Sheet No. 142
GENERAL TERMS AND CONDITIONS
(Continued)
13. MEASUREMENT
13.1 The unit of volume for measurement of all
quantities of Gas wheeled, parked, loaned or stored by TRES
PALACIOS or delivered to and received from storage hereunder shall
be one (1) cubic foot of Gas at the base temperature of sixty
degrees Fahrenheit (60 degrees F) and at an absolute pressure of
fourteen and seventy-three hundredths (14.73) pounds per square
inch and dry. All fundamental constants, observations, records,
and procedures involved in determining and/or verifying the
quantity and other characteristics of Gas delivered hereunder
shall, unless otherwise specified herein, be in accordance with
the standards prescribed in Report No. 3 of the American Gas
Association, as now in effect and from time to time amended or
supplemented. All measurements of Gas shall be determined by
calculation into terms of such unit. All quantities given herein,
unless expressly stated otherwise, are in terms of such unit.
Notwithstanding the foregoing, it is agreed that, for all
purposes, the Btu content of the Gas received and delivered by
TRES PALACIOS hereunder shall be measured on a "dry" basis rather
than a fully saturated or "wet" basis. For Gas volumes reported
in cubic meters, the standard conditions are 101.325 kPa, 15
degrees C, and dry.
13.2 TRES PALACIOS shall install, maintain and operate,
or cause to be installed, maintained and operated, the measurement
facilities required hereunder. Said measurement facilities shall
be so equipped with meters, recording gauges, chromatographs or
other types of related and/or similar equipment of standard make
and design commonly acceptable in the industry, as to accomplish
the accurate measurement of Gas delivered hereunder. The
retrieval of data and calibrating and adjustment of meters shall
be done by TRES PALACIOS or its agent.
14. BILLINGS AND PAYMENTS
14.1 Invoice. Not later than the ninth (9th) Business
Day of each month, TRES PALACIOS shall provide Customer (including
a Replacement Customer) an invoice and any required backup data
(which may be transmitted by fax) setting forth (i) the charges
due for the current Month; (ii) the total quantity of Gas, stated
in Dekatherms, received from and delivered to Customer hereunder
during the preceding Month(s), with applicable Point(s) of Receipt
and Point(s) of Delivery properly identified, and the amount due
therefor; and if applicable, (iii) the amount of Customer's Gas in
storage as of the close of the preceding Month and information
sufficient to explain and support any adjustments made by TRES
PALACIOS in determining the amount billed. If actual quantities
are not available by the ninth (9th) Business Day of the month,
TRES PALACIOS may invoice based on best available data subject to
adjustment to actual at a later date. Quantities at points where
Operational Balancing Agreements exist shall be invoiced based on
scheduled quantities.