(d) Shall not contain more than 4% by volume of a combined total
of carbon
dioxide and nitrogen components; provided, however, that the
total carbon
dioxide content shall not exceed 2% by volume.
(e) Shall have been dehydrated, if necessary, for removal of
water present
therein in a vapor state, and shall in no event contain more than
7 pounds of
entrained water per MMcf of Gas as determined by standard methods
of testing.
(f) Shall not exceed a temperature of 120? Fahrenheit.
(g) Shall be as free of oxygen as practicable and shall not in
any event
contain more than 0.4% by volume of oxygen.
(h) Shall in no event contain any mix of components that will
cause the
presence of any liquids in the pipeline under normal operating
conditions.
2.2 The party measuring Gas quality shall use approved standard
methods in
general use in the Gas industry, and shall cause adequate tests
to be made to
determine the quality of the Gas delivered. Such tests shall be
made at
intervals frequent enough to determine that the Gas conforms to
these
specifications.
2.3 If the Gas being received by Transporter from Shipper or on
behalf of
Shipper fails at any time to conform to any of the specifications
set forth in
Section 2.1, Transporter may refuse to receive the Gas, in which
case
Transporter shall notify the Person delivering such Gas of such
deficiency in
quality to allow such Person to remedy any deficiency. Upon such
Person's
failure to promptly remedy any deficiency in quality as specified
in Section
2.1, Transporter may terminate all receipts under the
Transportation Agreement
or accept delivery of such Gas and may make changes necessary to
bring such
Gas into conformity with such specifications, and the Shipper
shall reimburse
Transporter for any reasonable expense incurred in effecting
such changes or
for any injury or damages resulting from deliveries of
non-conforming Gas.
2.4 The design and construction of any facilities to be
installed by Shipper
in order to comply with the quality specifications in Section 2.1
shall be
approved by Transporter prior to such facilities being placed in
service, such
approval not to be unreasonably withheld.
3. MEASUREMENT
3.1 The volume and the total heating value of Gas received and
delivered by
Transporter shall be determined as follows: