Texas Gas Transmission, LLC

Third Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 03/04/2010, Docket: RP10-360-000, Status: Effective

First Revised Sheet No. 2404 First Revised Sheet No. 2404

Superseding: Original Sheet No. 2404

 

GENERAL TERMS AND CONDITIONS

Section 12

(Cont'd)

 

 

Receipt of Nominations by transporter, including 5:15 p.m.

from TTTSPs Day of flow

 

Texas Gas provides quick response for

validity of data elements 5:30 p.m.

Day of flow

Receipt of completed confirmations by transporter

from upstream and downstream connected

parties 8:00 p.m.

Day of flow

Scheduled Quantities made available by Texas

Gas to affected shippers and point operators -

No bumping allowed under Cycle No. 2

Nominations 9:00 p.m.

Day of flow

 

Effective Flow Time 9:00 p.m.

Day of flow

 

(iv) Intra-Day Nomination A.M. Processing Cycle for WNS Service:

 

Nominations hourly, 9:00 a.m.

to 11:00 a.m.

Day of flow

 

Effective Flow Time no earlier than 2

hours from when

request is received

 

(v) Intra-Day Nomination P.M. Processing Cycle for WNS Service:

 

Nominations hourly, 4:00 p.m.

to 6:00 p.m.

Day of flow

 

Effective Flow Time no earlier than 2

hours from when

request is received

 

(c) All nominations, including intra-day nominations, shall be based on a

daily quantity; thus, an intra-day nominator need not submit an hourly

nomination. Intra-day nominations shall include an effective date and

time. The interconnected parties shall agree on this hourly flow of

the intra-day nomination, if not otherwise addressed in Texas Gas'

contract or tariff.

 

(d) Texas Gas will schedule Intra-Day nominations, subject to it being

able to confirm and verify such nomination change at both receipt and

delivery points. Texas Gas will provide notice to shippers of mid-day

bumping of interruptible service as described herein by phone or

facsimile as elected by shipper, until such time as Texas Gas provides

direct notice of such bumping using Internet email or direct

notification to shipper's URL address consistent with Order No. 587-G.

 

12.6 Customers electing to utilize Point(s) of Receipt and/or Point(s) of Delivery

available on third party pipeline systems within the capacity contracted for

and utilized by Texas Gas pursuant to Section 25.8 of the General Terms and

Conditions, must provide nominations to Texas Gas in accordance with this

Section 12 or three (3) hours prior to nomination and scheduling deadline(s)

of the third party pipeline, whichever is earlier.