Texas Gas Transmission, LLC
Third Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 04/01/2009, Docket: RP09-405-000, Status: Superseded
First Revised Sheet No. 1254 First Revised Sheet No. 1254
Superseding: Original Sheet No. 1254
RATE SCHEDULE ISS-M (Continued)
6. Winter Season Provisions
During the Winter Season, Pipeline will deliver to Customer up to Customer's Maximum
Daily Withdrawal Quantity and Customer's Maximum Seasonal Quantity as set forth
below.
6.1 Customer will be required to nominate from storage into Pipeline's system a
quantity of gas up to the Maximum Daily Withdrawal Quantity.
6.2 Seasonal Minimum & Maximum Withdrawal - No less than 68% of Customer's Maximum
Seasonal Quantity shall be withdrawn each Winter Season if Customer has renewed its
ISS-M service for the subsequent storage contract year. If ISS-M service has not
been renewed, Customer will be required to withdraw 100% of its Seasonal Quantity
such that its storage balance is zero before March 31 of the Storage Contract Year.
6.3 Customer electing not to renew their ISS-M service for the subsequent Storage
Contract Year must withdraw any remaining volumes within 30 days or forfeit
said volumes to pipeline.
6.4 Pipeline shall deliver to Customer gas for Customer's account only when
Customer's storage inventory is greater than zero.
7. Summer Season Provisions
Pipeline shall receive from Customer during each Summer Season up to the Maximum
Seasonal Quantity at daily rates not to exceed the Maximum Daily Injection Quantity.
7.1 Inventory verification tests will be conducted on a semiannual basis. These
tests require the temporary suspension of individual storage field activities
(injections and withdrawals) for a period of approximately two weeks. If
conditions will not permit the full maximum daily injection or withdrawal
quantity, Texas Gas may temporarily adjust the limit. Texas Gas will provide
at least 45 days notice on its EBB with regard to the scheduling of these
shut-in periods to allow customers to adjust for the interruption of storage.
7.2 To assist Pipeline's operational and maintenance scheduling through the
Summer Season, Customer will notify Pipeline by March 15 of each year, with
updates monthly, of the quantities it intends to inject monthly during the
immediately upcoming Summer Season; such injection schedule provided by
Customer is a best efforts estimate and may be revised as necessary.
Pipeline will use its reasonable efforts to coordinate its test, maintenance,
alteration and repair activities during such Summer Season to accommodate
Customer's request.
7.3 If Customer desires Pipeline to store gas for Customer's account under this
Rate Schedule, it shall give notice to Pipeline specifying the quantity of
gas which Customer desires to be injected into storage under this Rate
Schedule on such day. Pipeline shall thereupon inject the quantity of gas so
nominated subject to the limitations set forth herein.
7.4 Pipeline shall be obligated to accept gas for storage for Customer's account only
when Customer's Storage Inventory is less than Customer's Maximum Seasonal
Quantity.
8. General Terms and Conditions
All General Terms and Conditions of Texas Gas' FERC Gas Tariff are applicable to this
Rate Schedule and are hereby incorporated as a part of this Rate Schedule ISS-M.