Texas Gas Transmission, LLC
Third Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 08/09/2010, Docket: RP10-956-000, Status: Effective
Second Revised Sheet No. 904 Second Revised Sheet No. 904
Superseding: Original Sheet No. 904
RATE SCHEDULE ISS (cont'd)
7. Winter Season Provisions
During the Winter Season, Pipeline will deliver to Customer up to Customer's Maximum
Daily Withdrawal Quantity and Customer's Maximum Seasonal Quantity as set forth below.
7.1 Customer will be required to nominate from storage into Pipeline's system a
quantity of gas up to the Maximum Daily Withdrawal Quantity.
7.2 Seasonal Minimum & Maximum Withdrawal - No less than 68% of Customer's Maximum
Seasonal Quantity shall be withdrawn each Winter Season if Customer has renewed
its ISS service for the subsequent storage contract year. If ISS service has
not been renewed, Customer will be required to withdraw 100% of its Seasonal
Quantity such that its storage balance is zero before March 31 of the Storage
Contract Year.
7.3 Customer electing not to renew their ISS service for the subsequent Storage
Contract Year must withdraw any remaining volumes within 30 days or forfeit
said volumes to pipeline.
7.4 Pipeline shall deliver to Customer gas for Customer's account only when
Customer's storage inventory is greater than zero.
8. Summer Season Provisions
Pipeline shall receive from Customer during each Summer Season up to the Maximum
Seasonal Quantity at daily rates not to exceed the Maximum Daily Injection Quantity.
8.1 Inventory verification tests will be conducted on a semiannual basis. These
tests require the temporary suspension of individual storage field activities
(injections and withdrawals) for a period of approximately two weeks. If
conditions will not permit the full maximum daily injection or withdrawal
quantity, Texas Gas may temporarily adjust the limit. Texas Gas will provide at
least 45 days notice on its Internet Website with regard to the scheduling of
these shut-in periods to allow customers to adjust for the interruption of
storage.
8.2 To assist Pipeline's operational and maintenance scheduling through the Summer
Season, Customer will notify Pipeline by March 15 of each year, with updates
monthly, of the quantities it intends to inject monthly during the immediately
upcoming Summer Season; such injection schedule provided by Customer is a best
efforts estimate and may be revised as necessary. Pipeline will use its
reasonable efforts to coordinate its test, maintenance, alteration and repair
activities during such Summer Season to accommodate Customer's request.
8.3 If Customer desires Pipeline to store gas for Customer's account under this
Rate Schedule, it shall give notice to Pipeline specifying the quantity of gas
which Customer desires to be injected into storage under this Rate