Texas Gas Pipe Line Corporation
Third Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 06/01/1990, Docket: RP90-112-000, Status: Effective
Original Sheet No. 6 Original Sheet No. 6 : Effective
RATE SCHEDULE G-2 (Cont'd)
5. MINIMUM ANNUAL BILL AND ADJUSTMENT
If on any day when called upon by Buyer, Seller fails to
deliver any quantities requested by Buyer up to the Daily Contract
Maximum, then the minimum Annual Bill during the year in which such
failure occurs shall be reduced by an amount computed by multiplying
the total of the quantities of gas which Seller failed to deliver
of the quantities requested by Buyer on any day or days during such
year by the above specified rate.
6. DAILY CONTRACT MAXIMUM
The Daily Contract Maximum shall be the volume of gas specified
in the executed Service Agreement between Seller and Buyer.
7. HOURLY AND DAILY RATES OF TAKE
Consistent with the operation of Seller's pipeline system,
Buyer shall take and Seller shall deliver gas as nearly as practical
at uniform hourly rates of flow as requested by Buyer.
8. HEAT CONTENT ADJUSTMENT
If the heating value of gas delivered by Seller to Buyer shall
be below 1,000 Btu per cubic foot, the charges otherwise payable for
such gas shall be reduced by a quantity determined by multiplying
the charges otherwise payable for such gas by a fraction whose
numerator shall be the deficiency in heating value per cubic foot
below 1,000 Btu and whose denominator shall be 1,000.
9. MEASUREMENT BASE
Refer to Section 2.1 of the General Terms and Conditions.
10. GENERAL TERMS AND CONDITIONS
The General Terms and Conditions are applicable to this rate
schedule and are hereby made a part thereof.