Southern Natural Gas Company
Seventh Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 01/09/2009, Docket: RP09-147-000, Status: Effective
Fifth Revised Sheet No. 126A Fifth Revised Sheet No. 126A
Superseding: Fourth Revised Sheet No. 126A
GENERAL TERMS AND CONDITIONS
(Continued)
Section 12.2(b) (continued)
(b) Intraday Nominations: Any SHIPPER may revise its nomination in effect by
submitting a revised daily nomination to COMPANY on the day the change is
requested to be effective. COMPANY will support two intraday nomination cycles.
In the first cycle, the intraday nomination shall leave the control of the
nominating party by 10:00 a.m. and COMPANY must receive such nomination no later
than 10:15 a.m. Central Clock Time. COMPANY will have until 10:30 a.m. to send
a quick response, until 1:00 p.m. to complete confirmation and until 2:00 p.m.
to provide scheduled quantities to affected shippers, point operators and bumped
parties. Subject to further provisions of this Section 12 regarding scheduling
and confirmation, SHIPPER's intraday nomination will be effective as of 5:00 p.m.
Central Clock Time on the same gas day. In the second intraday nomination cycle,
the intraday nomination shall leave the control of the nominating party by
5:00 p.m. and must be received by COMPANY by 5:15 p.m. COMPANY will have until
5:30 p.m. to send a quick response, until 8:00 p.m. to complete confirmations
and until 9:00 p.m. to provide scheduled quantities to affected SHIPPERS and
point operators. Scheduled Quantities resulting from the second intraday
nomination cycle shall become effective at 9:00 p.m. on the same gas day. No
bumping of flowing gas shall occur as a result of the second intraday nomination
cycle. SHIPPER may request increases or decreases in total flow, or changes to
receipt points or delivery points of scheduled gas. For intraday nominations
under this Section, there is no limitation as to the number of intraday
nominations which a service requester may submit at any one standard nomination
cycle or in total across all standard nomination cycles. The intraday nomination
cycles set forth above shall apply to nominations from TTT Service Providers.
(c) All provisions of this Section 12 shall apply to intraday nominations;
provided that Intraday nominations and Evening Cycle nominations shall span one
day only and will not rollover or replace the remainder of a standing nomination.
(d) No-Bump Rule for Interruptible Nominations: SHIPPER may not nominate
to increase its existing flowing quantities at any Receipt Point or
Delivery Point to an IT Service Agreement if such increase would cause
the reduction of existing quantities flowing at said points; provided,
however, that a scheduled temporary reduction in the quantities being
transported on behalf of SHIPPER, when requested by SHIPPER and approved
by COMPANY or when requested by COMPANY for maintenance or construction, shall not
serve to establish a reduced level of existing flowing quantities for the purposes
of this provision.
SHIPPER also may not nominate to increase its existing flowing quantities
at any Exhibit A-1 Receipt Point or Exhibit B-1 Delivery Point to a
Service Agreement under Rate Schedule FT or FT-NN if such increase would
cause the reduction of existing quantities at said points for other
firm shippers; provided, however, that a scheduled temporary reduction in
quantities being transported on behalf of SHIPPER, when requested by SHIPPER
and approved by COMPANY, shall not serve to establish a reduced level of
existing flowing quantities for the purposes of this provision.