Southern Natural Gas Company
Seventh Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 11/01/1993, Docket: RS92- 10-003, Status: Effective
Original Sheet No. 110 Original Sheet No. 110 : Effective
GENERAL TERMS AND CONDITIONS
(Continued)
Related Hydrocarbon Fluids, AGA Report No. 3 -- ANSI/API 2530,
as revised September 1985, and as such report may hereafter be
further revised. Exact measurements of inside diameters of meter
tubes shall be obtained by means of a micrometer to the nearest one-
-thousandth inch. Said volumes shall be corrected for flowing
temperature and specific gravity in accordance with the provisions of
paragraphs (c) and (d) below.
(c) The flowing temperature of the gas shall be determined for the
purpose of measured volume correction. Volume shall be corrected
for each degree of variation in the flowing temperature from 60
degrees Fahrenheit. The flowing temperature will be measured by
RTD's, thermocouples, thermometers, etc. and shall be either (1)
recorded using charts, digital recorders, etc., in which case the tem-
perature at which gas was measured for the period of such record shall
be the arithmetic average of the record during the period of time
during which gas was flowing, or (2) used for on-site flow computations
in electronic flow computers in which case the instantaneous
measurement of temperature will be used in such computations.
Where no temperature measuring device is installed, the temperature
of the gas shall be assumed to be 60 degrees Fahrenheit.
(d) A specific gravity correction shall be applied to measured volumes.
The specific gravity to be used for such correction shall be determined
at an appropriate location by a gravitometer, chromatograph or other
device of standard manufacture and shall be either (1) recorded using
charts, digital recorders, etc., in which case an arithmetic average (to
be determined during the period of time during which flow was
occurring at the location of the specific gravity recorder) of such record
shall be the specific gravity of the gas being measured, or (2) used for
flow computations in electronic flow computers in which case the value
of the specific gravity being measured will be used as appropriate in
such computations. If a specific gravity measuring device is not
installed or available at an