16.9 Other Tests
Other tests to determine water content, sulfur, and
other impurities in the gas shall be conducted by the
Measuring Party as necessary and shall be conducted
according to standard industry testing procedures. Shipper
may request additional test(s) during normal business hours
upon reasonable notification, and Measuring Party shall
perform such test(s). Shipper shall bear the cost of such
test(s) in the event the additional test result(s) yield a
Monthly MMBTU value within 2.0% of the original test MMBTU
value; otherwise Measuring Party shall bear the cost of such
test(s).
16.10 Reporting
The reporting basis for Btu on the VGS System will be
14.73 dry psia and 60 degrees F (101.325 KPa and 15 degrees
C and dry). The reporting basis for Gigacalorie on the VGS
System will be 1.035646 Kg/cm2 and 15.6 degrees C and dry.
The reporting basis for gas volumes on the VGS System
will be cubic foot at standard conditions of 14.73 psia, 60
degrees F, and dry. For gas volumes reported in cubic
meters, the standard conditions are 101.325 kPA, 15 degrees
C, and dry.
For reporting purposes, Btu conversion factors will
be reported to not less than three (3) decimal places and
pressure base conversion factors will be reported to not
less than six (6) decimal places. For calculation purposes,
not less than six (6) decimal places will be used for both
conversion factors.