16.7 Relative Density
Gas samples obtained per Section 16.6 shall be
analyzed for the determination of the relative density of
the gas delivered hereunder. The result shall be obtained
to the nearest one-thousandth (0.001) and shall be applied
during the applicable period for the determination of gas
volumes delivered. At Measuring Party's option, relative
density may be obtained using an in-line continuous
gravitometer; in such case the in-line gravitometer shall be
accurate to within 0.25% of full scale.
Each Month, the relative density will be calculated
using the latest gas analysis.
16.8 Gross Heating Value
Samples obtained under the terms of Section 16.6
shall have the Gross Heating Value calculated from a gas
analysis according to the latest revision of GPA 2172. All
spot and continuous samples shall be retained for a minimum
period of thirty (30) days for verification in the event of
a disagreement. The Gross Heating Value of the C6+
components of the natural gas shall be determined at least
quarterly.