Mogas Pipeline LLC (Fomerly Missouri Interstate Gas)

First Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 06/01/2008, Docket: CP06-407-002, Status: Effective

Original Sheet No. 54 Original Sheet No. 54 : Pending

 

 

GENERAL TERMS AND CONDITIONS

(Continued)

 

3. Quality (continued)

 

(g) Hydrogen Sulphide. The gas shall not contain more

than one grain of hydrogen sulphide per one hundred (100) cubic

feet.

 

(h) Total Sulphur. The gas shall not contain more than

twenty grains of total sulphur per one hundred (100) cubic feet.

 

(i) Heating Value. The gas shall have a gross heating

value of not less than nine hundred fifty (950) and not greater

than eleven hundred (1,110) Btu per cubic foot of gas.

 

(j) Temperature. The gas shall not be delivered or

redelivered at a temperature in excess of one hundred twenty

degrees Fahrenheit (120oF).

 

3.2 Hazardous Substances. The gas received or delivered

under the terms of the Service Agreement shall contain no

"hazardous substance" as that term is defined in Section 101(14)

of the Comprehensive Environmental Response, Compensation, and

Liability Act, as amended, 42 U.S.C. 9601(14), except as

otherwise permitted by the terms of this tariff or Customer's

Service Agreement.

 

3.3 If gas tendered to Transporter fails to meet the

specifications of this Tariff, the measuring Party shall notify

the other Party of such failure. The receiving Party may refuse

to accept such gas. The Party tendering non-specification gas

hereunder shall indemnify the receiving Party for any injury,

damage, loss, or liability caused by the delivery of such gas,

except to the extent the receiving Party knowingly and willingly

accepts such non-specification gas.

 

4. Measurement

 

4.1 The transportation unit of gas received and delivered by

Transporter shall be a dekatherm.

 

4.2 Transporter shall have the right to rely on the

Delivering Pipeline's measurements and statements for quantities,

heating values, and specific gravity of gas received by

Transporter.

 

4.3 The closing of measurement shall be the later of the

fifth (5th) Business Day after the close of the month or the

third Business Day after Transporter receives a statement from

the Delivering Pipeline stating the quantities delivered to

Transporter.

 

4.4 (a) Quantities delivered hereunder at each Receipt Point or

Delivery Point will be determined by either the Transporter or

Shipper responsible for measurement at such point. The heating

value, specific gravity and supercompressibility (Mol percent of

nitrogen and carbon dioxide) values of the gas shall be

determined at the beginning of the receipt and delivery and

annually thereafter, or at more frequent intervals as may be

found necessary in practice.