Mississippi Canyon Gas Pipeline, LLC
First Revised Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 12/20/1998, Docket: CP96-159-006, Status: Effective
Original Sheet No.76 Original Sheet No.76 : Effective
GENERAL TERMS AND CONDITIONS (cont'd)
3.2 Measurement of Volume (c) - (con't)
recording devices in which case the temperature at which gas was
measured for the period of such record shall be
the arithmetic average of the record during the
period of time during which gas was flowing, or
(2) used for on-site flow computations in
electronic flow computers in which case the
instantaneous measurement of temperature will be
used in such computations.
(d) A specific gravity correction shall be applied to
measured volumes. The specific gravity to be used for
such correction shall be determined at an appropriate
location from a continuous sampling device, by a
gravitometer, chromatograph or other device of standard
manufacture and shall be either (1) recorded using
digital recorders or other mutually agreeable recording
device in which case an arithmetic average (to be
determined during the period of time during which flow
was occurring at the location of the specific gravity
recorder) of such record shall be the specific gravity
of the gas being measured, or (2) used for flow
computations in electronic flow computers in which case
the value of the specific gravity being measured will
be used as appropriate in such computations. If a
continuous specific gravity measuring device is not
installed or available at an appropriate location, then
specific gravity shall be determined monthly from a
continuous sampling device or by a mutually agreeable
method.
(e) The gross heating value shall be determined at an
appropriate location from a continuous sampling
device, by a calorimeter, chromatograph or other
device of standard manufacture and shall be either
(1) recorded using digital recorders or other
mutually agreeable recording device in which case
an arithmetic average (to be determined during the
period of time during which flow was occurring at
the location of the gross heating value recorder)
of such record shall be the gross heating value of
the gas being measured, or (2) entered as an input
to electronic flow computers in which case the
gross heating value being measured will be used in
the computation of the Btu content of the gas. If
a gross heating value measuring device is not
installed or available at an appropriate location,
then the gross heating value shall be determined
monthly from a continuous sampling device or by a
mutually agreeable method.