NAESB WGQ Version 1.7 standard 1.3.2 (iii)
verbatim: 10:00 am for nominations leaving
control of the nominating party; 10:15 am for
receipt of nominations by the transporter
(including from TTTSPs); 10:30 am to send Quick
Response; 1:00 pm for receipt of completed
confirmations by transporter from upstream and
downstream connected parties; 2:00 pm for
Transportation Service Provider to provide
scheduled quantities to affected shippers and
point operators, and to provide scheduled
quantities to bumped parties (notice to bumped
parties), (central clock time on the gas day).
Scheduled quantities resulting from Intraday 1
Nominations should be effective at 5:00 pm on
gas day.
(c) Intraday 2 Nomination Cycle. Subsequent to the
Intraday 1 Nomination Cycle, as described in
Section 5.2(b), Shipper may alter its
nominations provided that the nomination given
by Shipper to Pipeline for deliveries starting
at 9:00 p.m. during the current Gas Day shall be
submitted to Pipeline no later than the time
specified in the nomination timeline below, or
such lesser period as is acceptable to Pipeline.
Any scheduling nomination submitted after the
Timely Nomination Cycle shall contain Shipper's
anticipated service requirements for one Gas Day
only and shall include the effective date and
time. Intraday 2 nominations shall span one Gas
Day and will not rollover or replace the
remainder of a standing nomination. No
scheduled shippers shall be bumped during the
Intraday 2 Nomination Cycle. The nomination
timeline shall be CCT on the day of gas flow.