UGI LNG, Inc

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 06/01/2009, Docket: RP09-365-000, Status: Effective

Original Sheet No. 43 Original Sheet No. 43

 

computers may be used, at pipeline's option, to determine gas

quantities. Static and differential pressures shall be recorded

by Company.

 

(b) Joint Presence

 

Each party shall have the right to be present at the time of

installing, reading, cleaning, changing, repairing, inspecting,

testing, calibrating, or adjusting done in connection with

measuring equipment involved in billing and used in measuring or

checking the measurement of receipts and deliveries. The records

from such measuring equipment shall remain the property of their

owner, but upon request, each will submit to the other its records,

together with calculations therefrom for inspection and

verification, subject to return within ten (10) days after receipt

thereof.

 

(c) Installation

 

All installations of measurement equipment applying to or

affecting receipts and deliveries shall be made in such manner as

to permit an accurate determination of the quantity of natural

gas delivered and ready verification of the accuracy of

measurement. Care shall be exercised by Company and Customer

in the installation, maintenance and operation of pressure

regulating equipment so as to prevent any inaccuracy in the

determination of the quantity of gas received or delivered hereunder.

 

(d) Inaccurate Meter

 

In the event a meter is out of service, or registering

inaccurately, the quantity of natural gas received or delivered

shall be determined,

 

(i) By using the registration of any check meter or meters if

installed and accurately registering, or, in the absence of

(i),

 

(ii) By correcting the error or the percentage of error if

ascertainable by calibration, test, or mathematical

calculation, or in the absence of both (i) and (ii), then

 

(iii) By estimating the quantity of receipts or deliveries

during periods under similar conditions when the meter was

registering accurately.

 

(e) Verification

 

The accuracy of Company's measurement equipment shall be

verified by Company at reasonable intervals, and, if requested,

in the presence of representatives of Customer, but Company

shall not be required as a matter of routine to verify the