Pine Prairie Energy Center, LLC

Original Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 09/01/2007, Docket: RP07-563-000, Status: Effective

Original Sheet No. 141 Original Sheet No. 141 : Effective

 

GENERAL TERMS AND CONDITIONS

(Continued)

 

 

 

(a) Be commercially free from objectionable odors,

dirt, dust, iron particles, gums, gum-forming constituents,

gasoline, PCBs, and other solid and/or liquid matter, including

but not limited to water, Gas treating chemicals and well

completion fluids and debris, which may become separated from the

Gas during the transportation thereof.

 

(b) Contain not more than one fourth (1/4) of one

grain of hydrogen sulfide per one hundred (100) cubic feet, as

determined by the cadmium sulfate quantitative test, nor more than

twenty (20) grains of total sulfur per one hundred (100) cubic

feet.

 

(c) The Gas delivered hereunder shall not contain more

than two-tenths of one percent (0.2%) by volume of oxygen, shall

not contain more than three percent (3%) by volume of carbon

dioxide, shall not contain more than three (3%) by volume of

nitrogen, and shall not contain a combined total of carbon dioxide

and nitrogen components of more than four (4%) by volume.

 

(d) Have a heating value of not less than nine hundred

and sixty-seven (967) Btus per cubic feet and not more than eleven

hundred (1100) Btus per cubic feet.

 

(e) Have a temperature of not more than 120 degrees

Fahrenheit (120 degrees F), nor less than forty degrees Fahrenheit

(40 degrees F).

 

(f) Have been dehydrated by the tendering party, by any

method other than the use of a calcium chloride as desiccant, for

removal of entrained water in excess of seven (7) pounds of water

per million (1,000,000) cubic feet of Gas as determined by

dew-point apparatus approved by the Bureau of Mines or such other

apparatus as may be mutually agreed upon.

 

10.2 Rejection of Gas. Either party shall be entitled to

reject any Gas tendered to it by the other party which does not

meet the minimum specifications of Section 10.1 hereunder.

Acceptance of such Gas does not constitute any waiver of PPEC's

right to refuse to accept similarly nonconforming Gas.