Paiute Pipeline Company
Second Revised Volume No. 1-A
Contents / Previous / Next / Main Tariff Index
Effective Date: 11/05/2006, Docket: RP07- 12-000, Status: Effective
Second Revised Sheet No. 60 Second Revised Sheet No. 60 : Effective
Superseding: First Revised Sheet No. 60
GENERAL TERMS AND CONDITIONS
(Continued)
3. QUALITY (Continued)
3.2 Quality of Gas Delivered by Paiute at the Delivery
Point(s):
All gas delivered by Paiute to Shipper at the
specified Delivery Point(s) shall conform to the
following specifications:
(a) Sulfur Content: The gas shall not contain
more than one quarter (0.25) of one (1) grain
of hydrogen sulfide nor more than twenty (20)
grains of total sulfur per one hundred (100)
cubic feet.
(b) Impurities: The gas shall be commercially
free of dust, gums and other solid matter.
(c) Liquids: The gas shall be free of water
and hydrocarbons in liquid form at the
temperatures and pressures at which the gas is
delivered.
(d) Odorization: The gas shall be odorized
consistent with the parameters set forth in
Section 192.625 of Title 49 of the Code of
Federal Regulations.
(e) Heating Content: Paiute is to tender
delivery to Shipper only natural gas which is
commercial in quality containing an average
gross total heating value of not less than 975
Btus per cubic foot.
4. OPERATING PROCEDURES
4.1 Receipt and Delivery Pressures:
(a) Receipt Point(s): Gas to be transported
by Paiute under transportation rate schedules
shall be delivered by Shipper to Paiute at the
specified Receipt Point(s) at pressures
necessary for the gas to enter Paiute's
system, but which do not exceed the maximum
allowable operating pressure of Paiute's
facilities at such Receipt Point(s). Paiute is
under no obligation to modify its line
pressures to permit the entry of Shipper's gas
into its system.