5. DEFINITIONS
5.1 Maximum Withdrawal Quantity. The Maximum Withdrawal Quantity shall
be the largest number of Dth Transporter may vaporize for, and Shipper
may receive from, Transporter's liquefied natural gas storage plant
under this Rate Schedule on any one day, subject to the limitations
described in Section 7 of this Rate Schedule, and shall be specified in
the executed Service Agreement between Transporter and Shipper.
5.2 Storage Capacity Volume. The Storage Capacity Volume shall be the
maximum quantity of gas in Dth which Transporter may liquefy and store
in liquid form for Shipper's account and shall be specified in the
executed Service Agreement between Transporter and Shipper.
5.3 Liquefaction Period. The Liquefaction Period shall be the seven
consecutive months beginning on April 1 of any year and extending
through the next succeeding October 31.
5.4 Vaporization Period. The Vaporization Period shall be the five
consecutive months beginning on November 1 of any year and extending
through the next succeeding March 31.
5.5 Working Gas Inventory. Shipper's Working Gas Inventory at any
particular time shall be the quantity of gas in storage in liquid form
for Shipper at such time.
5.6 Nominated Storage Volume. Shipper's Nominated Storage Volume shall
be the quantity of gas in Dth, up to Shipper's Storage Capacity Volume,
which Shipper nominates to have liquefied and stored in liquid form by
Transporter for Shipper's account and shall be provided to Transporter
in writing on or before April 1 of each year. Shipper upon ten (10)
days written notice to Transporter may elect to change its Nominated
Storage Volume during the liquefaction period. Such change shall not
reduce the Nominated Storage Volume below Shipper's Working Gas
Inventory at the time of election.
6. LIQUEFACTION INTO STORAGE FOR SHIPPER'S ACCOUNT
During a liquefaction period, Shipper may tender to Transporter for
liquefaction and storage sufficient quantities of gas to fill Shipper's
Storage Capacity Volume, subject to Transporter's obligations to
provide firm storage services under Rate Schedules LS- and LS-F. Such
tenders shall commence on April 1 and shall consist of uniform daily
quantities equal to 1/200th of Shipper's Nominated Storage Volume
(except for the last day of liquefaction) until Shipper's Storage