GENERAL TERMS AND CONDITIONS
4. MEASUREMENT REPORTING (Continued)
4.2 Computation of Volume from Meter Readings and Registrations
(Continued)
4.23 If positive displacement or turbine meters are used,
measurements of the volumes received or delivered at
flowing pressures and temperatures shall be
corrected to the volumetric measurement base by the
application of proper correction factors for (a)
absolute static pressure, (b) flowing temperature
and (c) supercompressibility. If an integrating
device is used, correction for the deviation from
Boyle's Law may be built into the device; otherwise
such correction shall be applied to the volume of
gas indicated.
4.3 Energy Quantity
4.31 Standard Reference Conditions
The standardized reporting basis for BTU is
14.73 dry psia and 60 degrees F(101.325 kPa and
15 degrees C, and dry). The standardized reporting
basis for gigacalorie is 1.035646 Kg/cm2 and
15.6 degrees C and dry. [2.3.9/v1.3]
4.32 Calculation of Energy Quantity
The energy quantity, based on Standard Reference
Conditions, is the product of the physical volume
measured, in thousands of cubic feet (Mcf) and the
gross heating value of the measured gas (Btu/cf).
4.33 Reporting/Calculation Accuracy
For reporting purposes, BTU conversion factors shall
be reported to not less than 3 decimal places. For
calculating purposes, not less than 6 decimal places
shall be used. [2.3.10/v1.0]
4.34 Energy Unit of Measurement
The reporting unit for energy quantity used by
Company will be Dekatherms (Dth) at Standard
Reference Conditions.