Midwestern Gas Transmission Company
SECOND REVISED VOLUME NO. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 09/01/1993, Docket: RS92- 41-003, Status: Effective
Original Sheet No. 57 Original Sheet No. 57 : Effective
GENERAL TERMS AND CONDITIONS
II. QUALITY
1. The provisions set forth below shall apply to all gas delivered to Transporter
by Shipper.
(a) all gas shall have a total heating value of not less than nine hundred
sixty-seven (967) Btus per cubic foot, and not more than eleven hundred
(1100) Btu's per cubic foot;
(b) all gas shall be commercially free (at prevailing pressure and temperature
in Transporter's pipeline) from objectionable odors, dust, hydrocarbon
liquids, water and any other substance that might become separated from
the gas in Transporter's facilities, and Shipper shall furnish, install,
maintain and operate such drips, separators, heaters, and other mechanical
devices as may be necessary to effect compliance with such requirements
(after having secured the prior approval of Transporter as to the design
and construction of such facilities, which approval shall not be
unreasonably withheld);
(c) all gas shall not contain more than twenty (20) grains of total sulphur,
nor more than one fourth (1/4) of one grain of hydrogen sulphide per one
hundred (100) cubic feet;
(d) all gas shall not contain more than two-tenths of one percent (0.2%) by
volume of oxygen and Shipper shall make every reasonable effort to keep
the gas free of oxygen;
(e) all gas shall not contain more than four percent (4%) by volume of a
combined total of carbon dioxide and nitrogen components; provided
however, that the total carbon dioxide content shall not exceed three
percent (3%) by volume;
(f) the temperature of all gas shall not exceed one hundred twenty degrees
(120ø) Fahrenheit;