Midwestern Gas Transmission Company

Third Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 01/01/2002, Docket: RP02- 72-000, Status: Effective

Original Sheet No. 218 Original Sheet No. 218 : Effective

 

 

GENERAL TERMS AND CONDITIONS

 

 

2. GAS QUALITY AND PRESSURE

 

2.1 Standards

 

The provisions set forth below shall apply to all gas delivered to Company by

Shipper:

 

(a) All gas shall have a Total Heating Value of not less than nine hundred

sixty-seven (967) Btu's per cubic foot, and not more than eleven hundred

(1100) Btu's per cubic foot.

 

(b) All gas shall be commercially free (at prevailing pressure and temperature

in Company's pipeline) from objectionable odors, dust, hydrocarbon

liquids, water and any other substance that might become separated from

the gas in Company's facilities, and Shipper shall furnish, install,

maintain and operate such drips, separators, heaters, and other mechanical

devices as may be necessary to effect compliance with such requirements

(after having secured the prior approval of Company as to the design and

construction of such facilities, which approval shall not be unreasonably

withheld).

 

(c) All gas shall not contain more than twenty (20) grains of total sulphur,

nor more than one fourth (1/4) of one grain of hydrogen sulphide per one

hundred (100) cubic feet.

 

(d) All gas shall not contain more than two-tenths of one percent (0.2%) by

quantity of oxygen and Shipper shall make every reasonable effort to keep

the gas free of oxygen.

 

(e) All gas shall not contain more than four percent (4%) by quantity of a

combined total of carbon dioxide and nitrogen components; provided

however, that the total carbon dioxide content shall not exceed three

percent (3%) by quantity.

 

(f) The temperature of all gas shall not exceed one hundred twenty degrees

(120°) Fahrenheit.

 

(g) All gas shall have been dehydrated by Shipper for removal of entrained

water present therein in a vapor state and in no event contain more than

seven (7) pounds of entrained water per million cubic feet; at a pressure

base of fourteen and seventy-three hundredths (14.73) pounds per square

inch and a temperature of sixty degrees (60°) Fahrenheit as determined by

dew-point apparatus approved by the Bureau of Mines or such other

apparatus as may be mutually agreed upon.

 

2.2 Prior Approval of Gas Quality Facilities

 

The design and construction of any facilities to be installed by Shipper, in

order to comply with the quality specifications in Subsection 2.1 above, shall

be approved by Company prior to such facilities being placed in service; such

approval not to be unreasonably withheld.