Original Sheet No. 126 Original Sheet No. 126

 

5.8 The Point of Delivery shall be at the outlet side of Pipeline's measuring facilities at

the point of connection between the facilities of Pipeline and those of Customer as set

forth in the applicable Service Agreement. Should any of Pipeline's lines, meters, and

like equipment which is necessary for Pipeline to install at or near the point of delivery be

on property of Customer, Customer grants to Pipeline the right of free use of such

premises and ingress and egress to such facilities at all times for the purpose of

installation, operation, repair, or removal. Such facilities of Pipeline shall be and remain

the property of Pipeline and may be removed upon the termination of deliveries to

Customer.

 

5.9 Operational Flow Orders (OFO) - Pipeline may issue an (OFO) to Customers under

any firm or interruptible Rate Schedule as it deems necessary to protect the integrity of

its system or any portion thereof. Pipeline's actions with respect to OFO are to be

reasonable, objective, and nondiscriminatory.

 

OFO's will be issued by 2:00 p.m. CCT. Nomination changes must be made by 8:00

a.m. CCT on the Gas Day following issuance of the OFO. The OFO will be effective

one Gas Day later (second Gas Day after issuance of the OFO), unless otherwise

provided in the order. Pipeline may make OFO's effective with a shorter notice if

necessary to protect the integrity of its system.

 

Notice of an OFO shall be provided to affected Customers by either internet E-mail,

direct notification to the Customer's internet URL address or facsimile transmission (to be

chosen by the affected Customer), pursuant to Section 284.12(c)(3)(vi) of the

Commission's Regulations. In addition, such notice shall also be posted on Pipeline's

Interactive Internet Website. Notice of such OFO shall specify nature of the problem

sought to be address, the anticipated duration of the required compliance, and the

parameters of such compliance. Pipeline will issue general, system-wide OFO's only

after it determines that it is not possible for it to issue an OFO on a specific portion of the

system.

 

In the event an OFO is issued, the Pipeline shall provide on a quarterly basis to the

affected Customers via the Pipeline's Interactive Internet Website a report detailing the

underlying causes warranting the issuance for the OFO and explaining why the actions

required by the OFO were necessary to alleviate the identified problems.