ANR Pipeline Company

Second Revised Volume No. 1

 Contents / Previous / Next / Main Tariff Index

 

 

Effective Date: 11/01/2006, Docket: RP06-613-000, Status: Effective

First Revised Sheet No. 42H First Revised Sheet No. 42H : Effective

Superseding: Substitute Original Sheet No. 42H

 

 

RATE SCHEDULE FTS-4

Firm Transportation Service (with Minimum Flow Condition)

 

 

1. AVAILABILITY

 

This Rate Schedule is available to any person, corporation, partnership or any other

party (hereinafter referred to as "Shipper") for the Transportation of Gas by

Transporter, subject to the following limitations:

 

(a) Transporter has determined that it has sufficient available and uncommitted

capacity to perform service requested by Shipper and such service is

operationally feasible; and

 

(b) Shipper and Transporter have executed an Agreement under this Rate Schedule, or

conformed an existing Agreement to be consistent with this Rate Schedule.

 

2. APPLICABILITY AND CHARACTER OF SERVICE

 

(a) This Rate Schedule shall apply to all Transportation Service rendered by

Transporter for Shipper pursuant to the executed Agreement under this Rate

Schedule.

 

(b) Transportation Service under this Rate Schedule shall consist of: (1) the

receipt of Gas on behalf of Shipper, (2) the Transportation of Gas, and (3) the

Tender of Gas for delivery by Transporter to Shipper, or for Shipper's account.

 

(c) Transportation Service under this Rate Schedule shall be firm, up to the Primary

Route MDQs specified in the executed Agreement.

 

(d) If Shipper fails to nominate by the Timely Nomination Cycle sufficient

quantities of Gas, up to its Primary Route MDQ, to enable Transporter to

provide FTS-4L service nominated by the Timely Nomination Cycle, Transporter

shall issue a Must Flow Order ("MFO") notice to Shipper as expeditiously as is

reasonably practicable via GEMStm or EDM, requiring Shipper to nominate at the

Primary Receipt and Delivery Points specified in the executed Agreement (or at

Secondary Receipt and Delivery Points subject to Section 2(h) below) the

quantity of Gas specified in the MFO notice. The quantity of Gas subject to

and specified in an MFO notice shall be up to but shall not exceed Shipper's

Primary Route MDQ. Within four (4) hours of receipt by Shipper of an MFO

notice, Shipper shall be obligated to submit nominations for the Service Day

and in the quantity and at the points set forth in the MFO notice. Once

scheduled, Transporter shall not be obligated to accept any revised nominations

from Shipper to the extent such revised nominations would affect Transporter's

ability to provide FTS-4L service nominated by the Timely Nomination Cycle.

Notwithstanding the foregoing, Transporter shall not issue an MFO notice to

accommodate new, or an increase in, FTS-4L service nominations submitted after

the Timely Nomination Cycle.

 

(e) The amount of Gas specified in the MFO notice(s) shall be determined based on

nominated quantities received from the affected FTS-4L Shippers for such Day

and such amount shall be allocated to Shipper(s) on the basis of Confirmed

Price (from lowest to highest); provided, however, that in the event of an

equal Confirmed Price among Shippers, the amount of Gas among those Shippers

shall be allocated on a pro-rata basis based on Primary Route MDQ.

 

(f) If Shipper, on any Day, fails to comply with the MFO notice or to tender and

take deliveries of the scheduled quantities of Gas that are necessary for

Transporter to provide service under Rate Schedule FTS-4L ("MFO obligations"),

Shipper shall be subject to a penalty of twenty-five dollars ($25.00), plus the

applicable spot price index as set forth in the Agreement, for each Dekatherm

of Gas that does not comply with such MFO notice or that is scheduled but not

tendered to Transporter.