Millennium Pipeline Company, L. L. C.
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 12/22/2008, Docket: CP98-150-011, Status: Effective
Original Sheet No. 284 Original Sheet No. 284
GENERAL TERMS AND CONDITIONS
(Continued)
(d) Shipper and Transporter shall have the right to be present at
the time of any installation, reading, cleaning, change of charts, repair,
inspection, test, calibration, or adjustment made in connection with
Transporter's or Shipper's measuring stations or equipment used to measure
gas received by Transporter for Shipper or delivered by Transporter to
Shipper.
(e) The Records from measuring equipment shall remain the property
of the operator of such equipment, but upon request the operator will submit
to the other party its Records, together with calculations therefrom, for
inspection, subject to return within 30 days after receipt thereof.
(f) Orifice meters shall be installed and operated, and gas
quantities computed, in accordance with AGA Report No. 3, American National
Standards Institute ANSI/API 2530, "Orifice Metering of Natural Gas", revised
Second Edition, 1985, applied in a practical and appropriate manner, except
that the supercompressibility factor shall be calculated in accordance with
Section 26.8 above.
(g) Turbine meters shall be installed and operated, and gas
quantities computed, in accordance with AGA Transmission Measurement
Committee Report No. 7, "Measurement of Gas by Turbine Meters", 1985 Edition,
applied in a practical and appropriate manner, except that the
supercompressibility factor shall be calculated in accordance with Section
26.8 above.
(h) Diaphragm meters shall be installed and operated, and gas
quantities computed, in accordance with ANSI B109.1 or B109.2, "Diaphragm
Type Gas Displacement Meters", 1986, applied in a practical and appropriate
manner, except that the supercompressibility factor shall be calculated in
accordance with Section 26.8 above.
(i) Rotary meters shall be installed and operated, and gas
quantities computed, in accordance with ANSI B109.3, "Rotary Type Gas
Displacement Meters", 1986, applied in a practical and appropriate manner,
except that the supercompressibility factor shall be calculated in accordance
with Section 26.8 above.