Millennium Pipeline Company, L. L. C.
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 12/22/2008, Docket: CP98-150-011, Status: Effective
Original Sheet No. 272 Original Sheet No. 272
GENERAL TERMS AND CONDITIONS
(Continued)
(f) The gas shall contain no more than four percent (4%) by volume of
a combined total of carbon dioxide and inert components. The carbon dioxide
content shall not exceed one and twenty-five hundredths percent (1.25%) by
volume.
(g) The gas shall contain no more than two (2) grains of total
sulphur per one hundred (100) standard cubic feet. The gas shall contain no
more than twenty-five hundredths (0.25) grains of hydrogen sulfide per one
hundred (100) standard cubic feet.
(h) The gas shall have a heating value of not less than 967 Btu
(British thermal units) per standard cubic foot, gross on a dry basis. The
gross heating value of the gas shall be calculated from analysis of the gas
by 1) an online chromatograph, or 2) taking spot or continuous samples of the
gas at such times as may be determined by Transporter. The gross Btu shall be
corrected for compressibility as calculated from a gas analysis by an
accepted type chromatograph (or other suitable instrument) for a cubic foot
of gas at a temperature of 60ºF, when containing no water vapor and at an
absolute pressure of 14.73 psia.
(i) The gas shall have a Wobbe Index of one thousand three hundred
(1,300) plus or minus six
percent (6%). The Wobbe Index is defined as that number obtained by dividing
the saturated heating value of the gas by the square root of its specific
gravity.
(j) The gas shall have a flowing temperature of no greater than
100ºF.
25.4 Additional Conditions for Receipt of Gas.
(a) Should gas received by Transporter from any source ever fail to
meet the above specifications, then Transporter may elect to either continue
to receive gas or refuse to take all or any portion of such gas until the gas
is brought into conformity with these specifications. Transporter reserves
the right to impose revised and/or further quality specifications at any time
should Transporter, in its sole discretion, deem it necessary to protect the
safety and/or integrity of its pipeline system,
operations, or deliveries to other customers.