Gulfstream Natural Gas System, L.L.C.
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 05/21/2002, Docket: CP00- 6-004, Status: Effective
Original Sheet No. 118 Original Sheet No. 118 : Effective
GENERAL TERMS AND CONDITIONS
(CONTINUED)
3. QUALITY
3.1 Heat Content. Heat content shall mean the gross heating
value per cubic foot of Gas delivered at each Receipt Point
and Delivery Point. The Gas at each Receipt Point shall
have a heat content not greater than 1075 BTUs per cubic
foot or less than 1000 BTUs per cubic foot when determined
on a dry basis. The Gas received and delivered shall have
a hydrocarbon dew point less than 25 Degrees Fahrenheit at
800 psig. Transporter shall have the right to waive such
BTU content limit if Transporter is able to accept such Gas
without affecting Transporter's operations. The total
heating value per cubic foot of Gas shall be determined at
each Receipt Point and at strategic location(s) determined
by Transporter to be represented for each Delivery Point by
standard methods accepted in the industry for this purpose.
The unit of quantity for the purpose of determining total
heating value shall be one (1) cubic foot of anhydrous Gas
at a temperature of sixty (60) degrees Fahrenheit and an
absolute pressure of 14.73 psia.
3.2 Freedom from Objectionable Matter. The Gas received and
delivered hereunder:
(a) shall be commercially free from dust or other solid
or liquid matter which might interfere with its
merchantability or cause injury to or interference
with proper operation of the lines, regulators,
meters and other equipment of Transporter;