2.2 (a) The volume of Gas delivered at each Receipt Point

and Delivery Point shall be calculated by means of

an electronic flow computer located at each

Receipt Point or each Delivery Point, in the

following manner:

 

(1) The volume of Gas delivered through an orifice

meter shall be computed in accordance with AGA

Report No. 3, properly using all factors set

forth therein.

 

(2) The volume of Gas delivered through a turbine

meter shall be computed in accordance with AGA

Report No. 7, properly using all factors set

forth therein.

 

(3) The volume of Gas delivered through an

ultrasonic meter shall be computed in

accordance with AGA Report No. 9, properly

using all factors set forth therein.

 

(4) The volume of Gas delivered through a positive

displacement meter shall be computed by

properly applying, to the volume delivered at

flowing Gas pressures and temperatures,

correction factors for (i) absolute static

pressure, (ii) flowing Gas temperature, and

(iii) compressibility ratio.

 

(b) The volume of Gas delivered shall be computed using

the standards and factors determined as follows:

 

(1) The unit of volume for the purpose of

measurement shall be one thousand cubic feet of

Gas at a temperature of sixty (60) degrees

Fahrenheit and a pressure of 14.73 pounds per

square inch absolute. For the purpose of

pricing hereunder, the Dekatherm equivalent of

such unit of volume shall be determined by

multiplying each such unit of volume by the

total heating value per cubic foot of the Gas

delivered hereunder (adjusted to a common

temperature and pressure base) and by dividing

the result by one thousand (1000).