Gulfstream Natural Gas System, L.L.C.
Original Volume No. 1
Contents / Previous / Next / Main Tariff Index
Effective Date: 05/21/2002, Docket: CP00- 6-004, Status: Effective
Original Sheet No. 112 Original Sheet No. 112 : Effective
GENERAL TERMS AND CONDITIONS
(CONTINUED)
2.2 (a) The volume of Gas delivered at each Receipt Point
and Delivery Point shall be calculated by means of
an electronic flow computer located at each
Receipt Point or each Delivery Point, in the
following manner:
(1) The volume of Gas delivered through an orifice
meter shall be computed in accordance with AGA
Report No. 3, properly using all factors set
forth therein.
(2) The volume of Gas delivered through a turbine
meter shall be computed in accordance with AGA
Report No. 7, properly using all factors set
forth therein.
(3) The volume of Gas delivered through an
ultrasonic meter shall be computed in
accordance with AGA Report No. 9, properly
using all factors set forth therein.
(4) The volume of Gas delivered through a positive
displacement meter shall be computed by
properly applying, to the volume delivered at
flowing Gas pressures and temperatures,
correction factors for (i) absolute static
pressure, (ii) flowing Gas temperature, and
(iii) compressibility ratio.
(b) The volume of Gas delivered shall be computed using
the standards and factors determined as follows:
(1) The unit of volume for the purpose of
measurement shall be one thousand cubic feet of
Gas at a temperature of sixty (60) degrees
Fahrenheit and a pressure of 14.73 pounds per
square inch absolute. For the purpose of
pricing hereunder, the Dekatherm equivalent of
such unit of volume shall be determined by
multiplying each such unit of volume by the
total heating value per cubic foot of the Gas
delivered hereunder (adjusted to a common
temperature and pressure base) and by dividing
the result by one thousand (1000).